TCX® (I) 150/250 (300) V
TCX (I) 150/250V 2P0.75
Nexans ref. 10170061
- 包装: Cut to length (m)
- 线对数: 2
- 三线组数: -
- 导线截面: 0.75 mm²
- 外径最小值: 10.0 mm
- Maximum outer diameter: 12.0 mm
- 近似重量: 153 kg/km
TCX (I) 150/250V 4P0.75
Nexans ref. 10170094
- 包装: Cut to length (m)
- 线对数: 4
- 三线组数: -
- 导线截面: 0.75 mm²
- 外径最小值: 12.0 mm
- Maximum outer diameter: 14.0 mm
- 近似重量: 216 kg/km
TCX (I) 150/250V 7P0.75
Nexans ref. 10170097
- 包装: Cut to length (m)
- 线对数: 7
- 三线组数: -
- 导线截面: 0.75 mm²
- 外径最小值: 14.5 mm
- Maximum outer diameter: 17.0 mm
- 近似重量: 353 kg/km
TCX (I) 150/250V 10P0.75
Nexans ref. 10170099
- 包装: Cut to length (m)
- 线对数: 10
- 三线组数: -
- 导线截面: 0.75 mm²
- 外径最小值: 17.5 mm
- Maximum outer diameter: 20.0 mm
- 近似重量: 473 kg/km
TCX (I) 150/250V 14P0.75
Nexans ref. 10170102
- 包装: Cut to length (m)
- 线对数: 14
- 三线组数: -
- 导线截面: 0.75 mm²
- 外径最小值: 19.5 mm
- Maximum outer diameter: 22.0 mm
- 近似重量: 610 kg/km
TCX (I) 150/250V 19P0.75
Nexans ref. 10183965
- 包装: Cut to length (m)
- 线对数: 19
- 三线组数: -
- 导线截面: 0.75 mm²
- 外径最小值: 21.5 mm
- Maximum outer diameter: 24.5 mm
- 近似重量: 768 kg/km
TCX (I) 150/250V 24P0.75
Nexans ref. 10259830
- 包装: Cut to length (m)
- 线对数: 24
- 三线组数: -
- 导线截面: 0.75 mm²
- 外径最小值: 24.0 mm
- Maximum outer diameter: 27.0 mm
- 近似重量: 926 kg/km
TCX (I) 150/250V 2T0.75
Nexans ref. 10073618
- 包装: Cut to length (m)
- 线对数: -
- 三线组数: 2
- 导线截面: 0.75 mm²
- 外径最小值: 12.0 mm
- Maximum outer diameter: 14.0 mm
- 近似重量: 230 kg/km
TCX (I) 150/250V 4T0.75
Nexans ref.
- 包装: Cut to length (m)
- 线对数: -
- 三线组数: 4
- 导线截面: 0.75 mm²
- 外径最小值: 13.0 mm
- Maximum outer diameter: 15.0 mm
- 近似重量: 290 kg/km
TCX (I) 150/250V 2P1.5
Nexans ref. 10170127
- 包装: Cut to length (m)
- 线对数: 2
- 三线组数: -
- 导线截面: 1.5 mm²
- 外径最小值: 12.5 mm
- Maximum outer diameter: 14.5 mm
- 近似重量: 260 kg/km
Description
Description
Standards
-
InstallationIEC 60092-350; IEC 60092-360; IEC 60092-376
-
TestIEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
TCX® (I) 150/250 V armoured individually screened twisted pair cables are used for telecommunication and instrumentation purposes. These cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) cables are also selected where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
Design
- Conductor:
Stranded bare copper class 2
- Insulation:
XLPE (cross-linked polyethylene)
- Individual screen:
Alu/polyester tape with a tinned copper drain wire
- Assembling:
Polyester tape
- Armour:
Bare copper braid
- Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour : grey
Marking
NEXANS 279 TCX (I) Nber of pairs/triads & cross section 150/250V 90C IEC 60092-376 IEC 60332-3-22 Cat. A WW YYYY *CE* Manufacturing n° + metric marking
Core identification
Pair: white / blue with printed pair number
Triad: white / blue / red with printed triad number
Characteristics
Characteristics
结构特性
结构特性
使用特性
使用特性
Resources
Resources
我们的网站
选择你的国家查找我们的产品和解决方案
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania